Can you repair a cracked heat exchanger on a gas furnace. The heat exchanger on a furnace is the section that keeps the combustion chamber and the breathing air separate 3. Dec 19, 2019 furnace efficiency highefficiency furnaces are more complex and more expensive than 80% furnaces. She said she had detectors and asked weather there could be possible danger of a fire breaking out. Furnace heatexchanger crack signs your furnace has one. A gas furnaces heat exchanger is another potential source of leaked carbon monoxide. Signs and symptoms of a cracked gas furnace heat exchanger. When someone asks us why their furnace smells like gas, the answer is almost always due to a leak in your furnaces heat exchanger, which can be serious for all sorts of reasons including possible fire hazards, explosions and carbon monoxide poisoning. The blower fan of the furnace then comes on and sends air around the exchanger, where it picks up the heat from the furnace wall, then continues into the ducts.
Even though your furnace may look and seem fine, dangerous gases could leak into your home. The heat exchanger in your furnace heats air traveling from one end to the other. Dangerous cracked heat exchangers in furnaces fossil fuels and cracked heat exchangers anyone who has an oil or gas boiler, oil or gas furnace, gas logs whether they be propane or natural gas, a gas stove or oven, or any woodburning appliance or fireplace, or appliance or heating device that burns fossil fuels you need a carbon monoxide. More commonly, the cause of a cracked heat exchanger is misapplication or poor maintenance of the furnace. In most cases, if the heat exchanger is cracked, your hvac company will recommend replacing the entire furnace. When the furnace is in an attic or crawlspace, very few contractors will agree to replace the heat exchanger. The extra air will cause the oxygen reading to change notably. Unless you are one of the top 3% of people who have all the money, replacing the furnace is going to hurt the pocket book if you have not planed for it, but it has to be done. May 20, 2016 what causes a heat exhanger in a furnace to crack and fail. Dont worry though, there are some simple steps you can take to avoid your heat exchanger failing before the lifespan of your furnace is up, including. Visually check heat exchanger for cracks you will find most cracks form near the back and where the heat exchanger metal bends, since this is where it will be weakest due manufacturer weakening the metal by bending.
One of the most common reasons a gas furnace can be taken out of service, is when the repair technician finds to a cracked heat exchanger. Inspect lennox pulse furnace heat exchanger assembly for any signs of corrosion or leakage. The dangers of a cracked heat exchanger help heating. Basically, the heat exchanger is where the furnace heats the air. All too often, furnaces are grossly oversized or used incorrectly which causes the heat exchanger to fail prematurely.
Old control valves can also cause a heat exchanger to crack. If we discover that a customers furnace has a cracked heat exchanger, we shut the furnace off at the electrical switch and gas valve and tag the appliance for repair. This component cycles heat out of the combustion chamber and into the plenum. I wasnt sure if it was so just wanted some info of the possible dangers if the heat exchanger cracked on a furnace. Dec 03, 2015 additionally, a clogged plumbing pipe could cause a backup in a floor drain, also making it appear that your furnace is leaking. Press this onto the furnace heat exchanger, and allow it to dry. It is usually an indicator of more trouble in the future, and should not be taken lightly. You can just have the heat exchanger replaced, but it is an expensive repair, and a new furnace is often the smarter investment. The cause of cracked heat exchangers avoid this common scam. Additionally, a clogged plumbing pipe could cause a backup in a floor drain, also making it appear that your furnace is leaking.
A cracked heat exchanger in a gas furnace is a serious safety issue. When a repair technician arrives, they can often see the cracks or holes that have appeared in the exchanger itself. An air pressure test has been performed on the heat exchanger and exhaust venting system. Carrier common furnace problems premature heat exchanger. Sometimes it is a design issue, sometimes it can be attributed to poor maintenance. Corrosion because of reaction between the combustion gas and the metal often because of improper venting can also weaken the metal to the point where cracks. May 02, 2016 the your heat exchanger is cracked so your furnace must be replaced scam duration.
Should i replace my heat exchanger or buy a new furnace. Even though your furnace may look and seem fine, dangerous gases could leak into your home and seriously affect, even kill, your family members. Once you work with high heat you will never want to go back to a hx. Heat exchanger can crack for various reasons and should be checked every time furnace is repaired or maintained. If a heat exchanger becomes cracked, then your heating system will not perform as it should. Consequently, maintaining and inspecting your furnace can help prevent costly furnace repairs. Cracked heat exchanger, heater maintenance tips, heater repair advice duration.
Hvac courses understanding your heat exchanger the. Dec 02, 2016 if you smell a distinctly chemical odor thats similar to formaldehyde, the odor likely results from a crack in the heat exchanger component of your furnace. If the heat exchanger is cracked, byproducts of the combustion process that takes place within the. Be on the watch for symptoms of a cracked heat exchanger like. Jan 19, 2009 many consumers live with dangerous furnaces and attachments cracked heat exchangers, blocked flue vents, patchwork duct systems, etc. A heat exchanger acts as a collection station for combustible gas and allows the gas to make the air reach a boiling hot temperature. I told her to replace due to possible carbon monoxide poisoning. Were you recently told that your furnace heat exchanger is cracked and needs to be replaced. Personally i will never go back to either propane or a heat exchanger.
If your heat exchanger has cracks, these cracks cause your furnace to perform inefficiently. Carbon monoxide is a byproduct of incomplete combustion of fuels such as petroleum and wood. Mar 11, 20 more commonly, the cause of a cracked heat exchanger is misapplication or poor maintenance of the furnace. Be good to your heat exchanger inside a heat exchanger is fire, soot, and carbon monoxideall substances that can escape if it cracks. A furnaces heat exchanger can use all sorts of fuel, and the type of fuel your furnace uses depends on preference, local climate and what type of fuel is readily available in your area. This is because air is leaking through the crack in the heat exchanger into the combustion chamber. Furnace with a cracked heat exchanger and flame rollout. Gas furnace pressure switch problems gray furnaceman. They can come inspect your furnace and determine if you do indeed have a cracked heat exchanger. Because it allows the exhaust fumes inside the exchanger to.
The heat of the combustion gas raises the temperature of the metal, and as the air from the blower passes around it, heat transfers to it. Many consumers live with dangerous furnaces and attachments cracked heat exchangers, blocked flue vents, patchwork duct systems, etc. If the furnace is a 90% efficient furnace, the condensate drain may be blocked. According to becca virden, the public relations spokeswoman at centerpoint energy, we do our best for our customer by putting their safety and comfort first, safety being first. A heat exchanger may crack under these circumstances. The heat exchanger contains the gas combustion chamber. Broken and leaking heat exchangers are responsible for about 1,500 deaths per year in the united states, and many more people are poisoned by exposure to toxic gasses that go unfiltered by defective heat exchangers.
Cracked or corroded gas furnace heat exchangers leak co and other poisonous gasses into the home living area though air ducts. Having a cracked heat exchanger can have a very adverse effect on the overall performance of your home heating equipment. Many manufacturers offer a lifetime warranty on heat exchangers or even 20 years on the heat exchanger warranty. The heat exchanger, or heater core, is the most important part of your furnace, as it is hub of all combustion and heatrelated activity. Jan, 2020 the heat exchanger in your furnace heats air traveling from one end to the other. The video below explains diagnosing pressure switch problems. A gas furnace heat exchanger should last for the life of the gas furnace. One of the most expensive repairs if your furnace is leaking water, a malfunctioning secondary heat exchanger could be the cause of a leaky furnace. A broken heat exchanger increases the risk of fire and can distribute carbon monoxide fumes throughout your. This trips a safety switch and shuts down the furnace. I went to a customers house whos heat exchanger was rusting on a 20 year old furnace. Many hvac contractors find cracked heat exchangers using visual analysis and use the results to recommend furnace replacement.
Not only is furnace performance an issue, but heat exchanger malfunctions can pose serious health and fire risks. A crack in the heat exchanger could also be at fault. Some holes or small openings may have been there for years. I open up the plenum and show the crack from the top. As air is circulated through the hvac system, it passes over the heat exchanger and absorbs thermal energy before its circulated throughout the house. This will most likely diagnose a leaking furnace heat exchanger. When a heat exchanger becomes damaged and the combustion fumes and gases mix with the clean air. Thick soot deposits can interfere with the heat exchange between the furnace an the air.
Oct 18, 2017 if the heat exchanger is cracked, byproducts of the combustion process that takes place within the component can spill out. We have written a lot of articles lately on how to troubleshoot problems with your furnace, but todays topic is a bit more serious. The most common mishap in a heat exchanger is a crack, which happens from the metal changing temperatures. Weve met with lots of homeowners looking for a second opinion about a supposedly cracked heat. From time to time furnaces do need to be cleaned, but soot buildup is usually not a problem. Signs the heat exchanger in your home furnace is cracked. Ease of maintenance would play a big roll too in my decision. If you have an iron heat exchanger, then you need to find an iron repair liquid, which uses chemical reactions to seal holes in iron. If you smell a distinctly chemical odor thats similar to formaldehyde, the odor likely results from a crack in the heat exchanger component of your furnace.
What causes excess soot buildup in a propane furnace. Heat exchanger cracks are a serious furnace repair issue. The average life any given furnace is 15 to 20 years and then it needs to be replaced. A warning about cracked heat exchangers in gas furnace. Dec 02, 2014 according to becca virden, the public relations spokeswoman at centerpoint energy, we do our best for our customer by putting their safety and comfort first, safety being first. Have you heard this one recently, you have a cracked heat exchanger and your furnace has to be replaced, today.
Jan, 2020 having a cracked heat exchanger can have a very adverse effect on the overall performance of your home heating equipment. The furnace heat exchanger is the one of the main components inside the gas furnace and its used to transfer the heat from the gas burner to the warm air thats blown into your home. If the furnace is generally in good condition and operates at a good efficiency but has suffered a cracked heat exchanger, one might consider a heat exchanger replacement when the cost of the total job is about half the cost of a new furnace and of course also if the furnace heat exchanger remains covered by the manufacturers warranty. Furnace heat exchanger replacement costs 2020 costimatesfurnace. I show how a furnace reacts when there is a crack in the heat exchanger. Danger of a furnace with a cracked heat exchanger servicemax. A damaged heat exchanger in a gas furnace is potentially dangerous to a homes occupants and should not be ignored.
Furnace location making the replacement on a furnace that is easy to access is difficult enough. Typically, a cracked heat exchanger is recognized when heat is no longer vented into the home, or the homes carbon monoxide detectors go off. Inspect secondary heat exchanger for dirt buildup and clean, as necessary. In the video above the furnace techs says the oxygen reading could rise as high as. Because the metal of the heat exchanger expands and then contracts as it heats and cools, the stress may eventually cause a crack to form on the exchanger. What caused my heat exchanger to fail check out these. If the heat exchanger is cracked, the oxygen reading will change a lot when the blower turns on. There are certain signs to look for to determine if the heat exchanger has been. If, however, there is a problem with the airtofuel ratio the furnace can produce more than the usual amount of soot. Mar 15, 2010 personally i will never go back to either propane or a heat exchanger. Because it allows the exhaust fumes inside the exchanger to leak into the air.
Cracked heat exchanger furnace trouble shooting help. The hot combustion gas in the heat exchanger heats up the metal walls. What caused my heat exchanger to fail check out these real. In a normal gas furnace, the flame will usually appear blue. For instance, propane might be readily available in bozeman, montana but it is unlikely that youd find propane as a means of furnace fuel in an off. What causes a heat exhanger in a furnace to crack and fail. Pour a little bit of the chemical on the hole, and leave it to dry until it seals around the exchanger. Cracked heat exchangers pose a risk of carbon monoxide poisoning carbon monoxide is produced by combustion but is typically vented safely from the furnace out of the home, but if the heat exchanger is cracked, carbon.
Dec 16, 2014 if your furnace smells like gas and you have ruled out the other, more obvious options, ensure that the smell is coming from your air vents called registers. Make sure you open a bunch of windows before testing this. Cost to repair furnace estimates and prices at fixr. Furnace heat exchangers what is a heat exchanger in a furnace. As a result, people are killed or injured every year from dangerously high levels of carbon monoxide gas leaking from furnaces and attachments that should have been repaired or replaced. A heat exchanger is made of thin metal, and as it heats up from the combustion of the furnace, it transfers the heat to the air being distributed through the house by the blower 3. Gas furnace heat exchanger failure exchanger longevity. A damaged or cracked heat exchanger is the cause of the leading cause of carbon monoxide poisoning in north america. Dec 02, 2015 a cracked heat exchanger allows air from the furnace blower to interfere with the flame causing it to flutter or even roll out. If it is a small hole or crack, then it is a minor issue that needs to be corrected generally by replacing the furnace or heat exchanger. In this way, the combustion gas heats the air without the gas having ever to come in contact with it. Beware of an unethical technician who finds a crack with a camera on a furnace that seems to be running just fine.